Accuracy : Standard 0.1%
Process temperature : -20°C...130°C(-4°F...266°F)
Pressure measuring range : 100 mbar...40 bar(1.5psi...600psi)
Process pressure / max. overpressure limit : 60 bar (900 psi)
Main wetted parts : Ceraphire
Max. measurement distance : 400 m (1312 ft) H2O
Absolute and gauge pressure Cerabar PMC51
Field of application
The Cerabar PMC51 digital pressure transmitter with capacitive, oil-free ceramic measuring cell is typically used in process and hygienic applications for pressure, level, volume or mass measurement in liquids and gases. It guarantees high degree of system safety thanks to vacuum-proof ceramic membrane with integrated breakage detection. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 / IEC 61511.
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to 130°C (-40 to 266°F), 150°C (302°F) for 1h
Measuring ranges: -1/0 up to 40bar (-15/0 to 600psi)
Accuracy: ±0.1%, "Platinum" ±0.075%
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Benefits
Product Description
Measuring principle | Absolute and gauge pressure |
Characteristic | Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire) |
Supply voltage | 4...20 mA HART 11,5...45V DC (Non Ex): Ex ia: 11,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy | Standard 0.1% Platinum 0.075% |
Long term stability | 0.2% of URL/ year 0.4% of URL/ 5 years 0.5% of URL/ 10 years |
Process temperature | -40°C...+130°C(-40°F...+266°F)+150°C for 1h(+302°F for 1h) |
Ambient temperature | -40°C...+85°C(-40°F...+185°F) |
Measuring cell | 100 mbar...40 bar(1.5 psi...600 psi) relative/ absolute |
Smallest calibratable span | 10 mbar (0.15 psi) |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 20:1 |
Max. overpressure limit | 60 bar (900 psi) |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2 Flange: DN25...DN80, ASME 1"...4", JIS 10K |
Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
Material process membrane | Ceramic |
Material gasket | Viton, EPDM, NBR, Kalrez |
Fill fluid | None, dry measuring cell |
Material housing | Die-cast aluminum, AISI 316L |
Communication | 4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex |
Safety approvals | SIL |
Design approvals | EN10204-3.1 NACE MR0175 |
Hygienic approvals | CoC ASME-BPE 3A, EHEDG |
Marine approvals | GL/ ABS/ LR/ BV/ DNV |
Drinking water approvals | NSF |
Successor | PMC51B |
![]() |