Brand Name : KACISE

Model Number : KLD801

Certification : CE,ISO9001

Place of Origin : CHINA

MOQ : 1pcs

Price : 200-800

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram, Paypal

Supply Ability : 10000pcs/month

Delivery Time : 5-7 working days

Packaging Details : carton box

Frequency : 80GHz

Output : two-wire /4...20mA/HART protocol

Explosion-proof : Exia IIC T6 Ga/Exd ia IIC T6 Gb

Protection : IP67

Range : 0.1m~100m

Medium : liquid, non-corrosive

Process pressure : -0.1~0.3 MPa

Power supply : Two-wire /DC24V

Contact Now

Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank


The Kacise OEM Radar Level Gauge is a remarkable device specifically designed for septic tank applications. With a measurement range of up to 10 meters, it utilizes 80G radar technology to ensure highly accurate and reliable level detection. The RS485 communication interface enables seamless integration with other control systems, allowing for efficient data transfer and remote monitoring. This radar level transmitter is built to withstand the harsh and corrosive environment of septic tanks. It offers stable performance, providing real-time and precise level information, which is crucial for proper septic tank management and maintenance. Its advanced features and durable construction make it an ideal choice for effectively monitoring the liquid levels in septic tanks and optimizing related processes.

1.Product Dimension
Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic TankKacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank



2. Working Principle

The radar antenna transmites narrow microwave pulse which will be reflected back when reaching the surface of the medium tested and then received again by the antenna system. The signals shall be transmitted to the electric circuit and then converted into level signals. As the transmission speed of microwave is so fast, the time used for the microwave transmission to the surface of the medium tested and then reflected back is almost 0.
Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank

3. Technical Features

⚫ Millimeter wave radar, the measurement accuracy can reach up to ±2mm, and the minimum measurement blind zone is 0.05m.
⚫ The smaller antenna size satisfies the measurement of more working conditions.
⚫ A variety of lens antennas, smaller launch angles, more concentrated energy, stronger echo signals, and higher reliability than other radar products under the same industrial and mining conditions.
⚫ It has stronger penetration and can be used normally in the case of adhesion and condensation.
⚫ The dynamic signal range is larger, and the measurement of low dielectric constant media is more stable.
⚫ Multiple measurement modes, radar response in fast measurement mode

4. Technical Specification and Model Selections

Medium liquid, non-corrosive
Measuring range 0.05m~10/20/30/60/100m
Process connection G1½A / 1½NPT thread / flange ≥ DN40
Process temperature -40~80℃
Process pressure -0.1~0.3 MPa
Antenna size 32mm lens antenna
Antenna material PTFE
Accuracy ±1mm
Protection class P67
Center frequency 80GHz
Launch angle
Power supply Two-wire /DC24V / Four-wire system/DC12~24V / Four-wire system/AC220V
Casing aluminum/plastic/stainless steel
Signal output two-wire /4...20mA/HART protocol Four-wire system: 4...20mA/ RS485 Modbus

5. Installation Requirements
When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.
Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic TankKacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank

6. Electrical Connection

Power Supply
(4~20) mA/HART(2 wire)
The power supply and the output current signal share a two-core shielded cable. Please refer to the technical data for the specific supply voltage range.

(4~20) mA(4 wire/6 wire)
The power supply needs to be powered separately, and a four-core shielded cable is used for the power supply and current signal (the current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).

RS485/Modbus
The power supply needs to be powered separately, and a four-core shielded cable is used for power supply and digital signal. (The current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).

7.Connection
Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank
8.Safety Guide

Please observe the requirements of the local electrical installation regulations! Follow local regulations for personnel health and safety. All operations on the electrical components of the instrument must be completed by professionals who have received formal training. Please check the nameplate of the instrument to ensure that the product specification meets your requirements. Please ensure that the power supply voltage is consistent with the requirements on the nameplate of the instrument.

9.Grade of Protection

This instrument fully meets the requirements of protection class IP66/67, please ensure the waterproofness of the cable sealing head. As shown below:
Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank
How to ensure that the installation meets the requirements of IP67:
Make sure the sealing head is not damaged.
Make sure the cable is not damaged.
Please make sure that the cables used meet the requirements of the electrical connection regulations.
Before entering the electrical interface, bend the cable down to ensure that water will not flow into the housing, see ①
Please tighten the cable gland, see ②
Please plug the unused electrical interface with a blind plug, see ③

10.Sensor linearity

Beam Angle
The beam angle is the beam angle at which the energy density of the radar wave reaches half of its maximum value (3dB width). Microwaves emit signals out of beam range and can be reflected by interfering objects.

Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank

Lens Antenna Diameter

Φ32mm

lens Antenna

Φ42mm

lens Antenna

Φ76mm

lens Antenna

Φ74.7mm

lens Antenna with air purge

Beam Angle

The larger the antenna size and the smaller the beam angle α, the less interference echoes will be generated.
For more accurate measurements, avoid installing any internal devices (such as limit switches, temperature sensors, bases, vacuum rings, heating coils, baffles, etc.) within the range of the signal beam.

KLD800 series product show

Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank


Product Tags:

RS485 Radar Level Gauge

      

Septic Tank Radar Level Gauge

      

10m 80G Radar Level Transmitter

      
China Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank wholesale

Kacise OEM Radar Level Gauge 10m 80G RS485 Radar Level Transmitter For Septic Tank Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)